SQFTLI-1109 Industrial & Logistics Park

Industrial & Logistics Park SQFTLI-1109 Share :

Logistics Park available at Chennai of total area 41000 sqft
Compare Remove

Product Specifications

Total Area 41000 Sq.ft.
Clear Height 8 m
Structure PEB
Flooring RCC
Office Area Yes
Fire Work Yes
Basic Electric Work Yes
Fire NOC Yes
CLU Clearance Yes
Labor Rooms Yes
Transformer Yes
City Chennai

Request a Quote

Please provide the following information and we will get back to you soon as possible with a quote, item marked with an asterisk (*) are required.

Product Information

Standard Building Specifications:1.Building structure & Size: Pre-engineered building: size 90 m x 153 m. 2.Building clear height: 8 m from floor finish level to bottom of supporting structure of the roof sheeting. 3.Internal bay size: 20-22.50m x 16.0m. 4.Roof: “Standing Seam” which is a premium roof system. 5.External wall: Precast concrete walls up to 3.0 m and metal panels up to roof. 6.RCC: floor 5T/m2 udl vacuum dewatered flooring with floor hardener. 7.Skylight: Polycarbonate sheets, approximately 3.5 to 4% of roof area. 8.Canopy: 4.5m wide from building wall and along docking side. 9.Dock height: 1.2 m from dock apron. 10.Docking type: Internal. 11.Dock doors type: Manually operated MS rolling shutter. 12.Dock door: size 2.4m x 3.0m 13.Dock pits: Dock pits to accommodate the dock leveller 14.Drive in door type: Manually operated MS rolling shutter 15.Drive in door size & number: 4m x 5m 16.Drive in ramp: Considered 17.Office area: Office area as mentioned in the area statement 18.Fire escape doors: Fire rated exit door (Vision panel, Panic bar, Door handle & Door closer) with steps. Door size & the 19.Truck apron: Concrete, 16.5 m (from face of dock wall to edge of pavement) 20.Ventilation system: Passive ventilation to provide minimum 3-6 air changes through louvered panels on external walls and roof monitor 21.Fire extinguisher: Hand -held fire extinguisher as per the local fire code 22.Fire hydrant: External fire hydrant system around the building & fire hose pipes within the building as per the local fire norms. 23.Fire tank & pump room: Underground/overhead fire water tank & pump room (common for the park) is available for the building & is a part of common infrastructure of the park. Pump sets are as per the local fire codes 24.Crash protection: Protection from the forklift impact to base of building’s façade and pillars and other elements like fire protection gates, electrical cabinet in warehouse area.  

Video

Brochure

Rating & Reviews

0 Comments
Questions & Answers

To be first to post questions.


Whatsapp Icon Whatsapp